FAQs Jiemate Ultra-High Pressure Test Pumps
As a leading test pump manufacturer, Henan Jiemate Equipment Co., Ltd. has always centered on customer needs, committed to providing high-quality and reliable ultra-high pressure test pump products and services. In response to typical questions frequently asked by users, we have compiled the following answers to help you quickly resolve usage doubts.
Q1: How to select a suitable test pump model?
A: Please refer to the following parameters according to actual needs:
Working pressure (Bar): Refer to the “rated discharge pressure” range (90-500Bar).
Flow requirement (m³/h): Select a matching flow value based on the operating scenario (e.g., 2.4-10.2m³/h).
Liquid properties: Clean water, emulsion, or chemical liquids require corresponding material configurations.
Jiemate provides plunger diameter customization services (22-45mm). For special working conditions, you can call the test pump manufacturer’s phone number 180-0385-3609 for selection suggestions.
Q2: Can non-standard pressure or flow parameters be customized?
A: Yes! As an ultra-high pressure test pump manufacturer, Jiemate can adjust power (30-90KW), pressure range, and flow parameters according to customer needs, providing one-stop customized solutions.
Q3: What precautions should be taken when installing the test pump?
A:Stable foundation: Ensure the equipment is placed on a flat and shock-resistant base.
Pipeline connection: Check the tightness of inlet and outlet pipes to avoid leakage.
Power matching: Verify the motor power and supply voltage (e.g., 380V industrial electricity).
Before the first start-up, it is recommended to run it without load for 5 minutes to observe if there is abnormal vibration or noise.
Q4: How to operate correctly to extend the equipment life?
A:Confirm that the lubrication system has sufficient oil before starting.
Avoid long-term overpressure operation (pressure should not exceed 10% of the rated value).
Drain the residual liquid in the pump in time after shutdown to prevent corrosion.
Q5: What work needs to be done for daily maintenance?
A:Daily inspection: Oil level, condition of seals, pipeline connections.
Monthly maintenance: Replace lubricating oil and clean the filter.
Annual maintenance: Fully check the wear of plungers and valves, and replace vulnerable parts if necessary.
Q6: What should I do if the equipment has unstable pressure?
A: Possible causes and handling steps:
Pipeline leakage: Check the tightness of each interface.
Insufficient liquid intake: Ensure the suction pipeline is not blocked and there is sufficient liquid.
Valve wear: Contact the after-sales team to replace valve components.
Q7: The test pump cannot start. How to troubleshoot?
A:Check if the power supply is connected and if the fuse is blown.
Confirm that the motor has not triggered overheating protection.
If the problem persists, please call the test pump manufacturer’s phone 180-0385-3609 immediately.
Q8: What does the after-sales service include?
A: Jiemate provides:
Technical consultation: 24-hour online answers to operational questions.
Accessories supply: Fast delivery of original vulnerable parts.
On-site service: Engineers’ on-site maintenance or debugging.
Q9: Is equipment operation training provided?
A: Yes! Purchasing Jiemate ultra-high pressure test pumps can get free operation manuals and on-site/remote training to ensure users master equipment usage skills proficiently.
Q10: How long is the equipment warranty period?
A: The whole machine is guaranteed for 1 year, and core components (such as plungers and motors) are guaranteed for 2 years, with lifelong technical support provided.